24 ساعة علي مدار الأسبرع
متاح 24 ساعة علي مدار الأسبوع
قسم كهرباء الباور
قسم التحكم الآلي
قسم الإضاءة
قسم النيوماتيك
عرض 33–64 من أصل 189 نتيجة
PILZ | 777305 | PNOZ X2.7P 24VACDC 3n/o 1n/c
PILZ | 312651 |PSSu BS 1/8C Basismodul Pi 312651V 1.1
Siemens | 5SY4116-6 |Miniature circuit breaker 230/400 V 10kA, 1-pole, B, 16A, D=70 mm
Siemens | 5TG1814 |
Schneider | A9HV318XI125 |A9HV318XI125 Schneider Electric Acti 9 Vertical TPN 18way with 3P isolator 125A incomer provision
FESTO | 537952 |Solenoid valve
VMPA2-M1H-M-PI
Siemens | 3RV1611-1DG14 |
Autonics | AI-M-56LA-B |utonics 2-Phase Closed-Loop Stepper Motor, 56mm Square, Single Shaft, 3.5A/Phase, 20.39Kgf.cm / 2.0N.m, Built-in brake
FESTO | 153216 |Multiple distributor
QSLV2-3/8-8
Siemens | 6AV6641-0CA01-0AX1 |
ABB | 2CDS274061R0084 |S204M-C8UC
Pepperl + Fuchs | 106394 |NJ2-12GM-N INDUCTIVE SENSOR, NAMUR, 2 MM SENSING DISTANCE, 5-25 VAC, 2000 HZ, N/C, 2 WIRE, -25 TO +1000 DEGREES C, IP66/67, 106394
في المخزون
voltage release XF – 200..250 V DC/AC 50/60 Hz
في المخزون
This is a MX opening voltage release for fixed Masterpact NT and NW devices. Its rated voltage is 200VDC to 250 VDC or 200VAC to 250 VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. It complies with IEC 60947-2 standard. Masterpact device can be equipped with 1 MX, 1 XF and 1 MN auxiliaries.
في المخزون
voltage release MN – 200..250 V DC/AC 50/60 Hz
في المخزون
This is a motor mechanism (MCH) for fixed MasterPact NT circuit breakers. The motor mechanism module is used to remotely open and close the circuit breaker electrically. It is made up of a spring-charging motor equipped with an opening release and a closing voltage release. The spring-mechanism charging handle is used only as a backup if auxiliary power is absent. It is equipped with a 10A limit switch contact (CH) that signals the charged position of the mechanism. The operational control voltage is 200/240 VAC 50/60 Hz. The operating threshold is between 0.85xUn and 1.1xUn. The charging time is less than 3s. The maximum operating frequency should not exceed 3 cycles per minute.
في المخزون
voltage release XF – 200..250 V DC/AC 50/60 Hz
في المخزون
This is a motor mechanism (MCH) for drawout MasterPact NT circuit breakers. The motor mechanism module is used to remotely open and close the circuit breaker electrically. It is made up of a spring-charging motor equipped with an opening release and a closing voltage release. The spring-mechanism charging handle is used only as a backup if auxiliary power is absent. It is equipped with a 10A limit switch contact (CH) that signals the charged position of the mechanism. The operational control voltage is 200/240 VAC 50/60 Hz. The operating threshold is between 0.85xUn and 1.1xUn. The charging time is less than 4s. The maximum operating frequency should not exceed 3 cycles per minute.
في المخزون
This is an adaptation feature for cable interlocking of two Masterpact NW08 to NW63 in fixed version. This adaptation fixture is mounted on the right side one device. For a complete interlocking assembly, another adaptation fixture and a set of cables are needed.
في المخزون
auxiliary contact – 4 OC
في المخزون
This is a motor mechanism (MCH) for drawout Masterpact NW circuit breakers. It allows remote opening or closing operations. It can be used for automatic source changeover. The control voltage is 200-240 VAC 50/60 Hz, and the charging time is less than 4s. It is equipped with a limit switch contact (CH) that signals the charged position of the mechanism.
في المخزون
It is an additional block of 4 contacts OF for Masterpact NW08 to NW63 devices. These auxiliary contacts provides OF remote information of the circuit breaker status. It is a rotary type changeover contacts directly driven by the mechanism for Masterpact NW. OF contact is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 6A and the minimum load is 100mA at 24 VDC. Utilization categories are AC12/DC12.
في المخزون
This is a XF closing voltage release for drawout Masterpact NW devices. Its rated voltage is 200VDC to 250 VDC or 200VAC to 250 VAC 50/60Hz. It is an auxiliary used for remote closing applications. This auxiliary closes the circuit breaker when the control voltage Un rises above 85% of its rated voltage Un. It complies with IEC 60947-2 standard. Masterpact device can be equipped with 1 MX, 1 XF and 1 MN auxiliaries.
في المخزون
This is a MX opening voltage release for drawout Masterpact NW devices. Its rated voltage is 200VDC to 250 VDC or 200VAC to 250 VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. It complies with IEC 60947-2 standard. Masterpact device can be equipped with 1 MX, 1 XF and 1 MN auxiliaries.
في المخزون
This is a MN undervoltage release for drawout Masterpact NW devices. Its rated voltage is 200VDC to 250 VDC or 200VAC to 250 VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage drops to a value below 35% of its rated voltage Un. It complies with IEC 60947-2 standard. Masterpact device can be equipped with 1 MX, 1 XF and 1 MN auxiliaries.
في المخزون
This is a motor mechanism (MCH) for drawout Masterpact NW circuit breakers. It allows remote opening or closing operations. It can be used for automatic source changeover. The control voltage is 200-240 VAC 50/60 Hz, and the charging time is less than 4s. It is equipped with a limit switch contact (CH) that signals the charged position of the mechanism.
في المخزون
cable interlocking for fixed or drawout – for Masterpact NW08..63
في المخزون
cable interlocking for fixed or drawout – for Masterpact NW08..63
في المخزون
cable interlocking for fixed or drawout – for Masterpact NW08..63
في المخزون
rod interlocking for fixed or drawout – for Masterpact NW08..63
في المخزون
This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 65A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 30 millimeters and the weight is 0.120kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 15 millimeters. The maximum cross section per phase (R, S, T, N) is 25mm² for a copper conductor.
في المخزون
This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 85A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 50 millimeters and the weight is 0.200kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 25 millimeters. The maximum cross section per phase (R, S, T, N) is 50mm² for a copper conductor.
في المخزون
This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 160A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 80 millimeters and the weight is 0.420kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 40 millimeters. The maximum cross section per phase (R, S, T, N) is 95mm² for a copper conductor.
في المخزون
This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 250A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 120 millimeters and the weight is 0.450kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 60 millimeters. The maximum cross section per phase (R, S, T, N) is 240mm² for a copper conductor.
في المخزون
This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 400A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 200 millimeters and the weight is 1.320kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 100 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 185mm² for a copper conductor.
في المخزون
This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 630A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 300 millimeters and the weight is 2.280kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 150 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 240mm² for a copper conductor.
في المخزون
external battery module, rechargeable, input 24 VDC, output 24 VDC / 40 mA max, 4h autonomy
في المخزون
This toroid is dedicated to VigiPacT type A residual current protection and monitoring relays. It allows the measurement of a current rating up to 1600A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner dimensions of the toroid are 280mm X 155mm and the weight is 11kg. The wiring size must be from 0.5 to 2.5 mm². The wiring length should not exceed 10m.
في المخزون
This toroid is dedicated to VigiPacT type A residual current protection and monitoring relays. It allows the measurement of a current rating up to 3200A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner dimensions of the toroid are 470mm X 160mm and the weight is 20kg. The wiring size must be from 0.5 to 2.5 mm². The wiring length should not exceed 10m.
في المخزون
VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 30mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
في المخزون
VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 300mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
في المخزون
VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 380/415VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 30mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
في المخزون
VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 380/415VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 300mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
في المخزون
VigiPacT RH21M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. The current sensitivity is selectable with 2 thresholds 30 mA and 300 mA. The time delay is instantaneous 0.06s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
ليس لديك حساب بعد؟
إنشاء حسابستيم الإستخدام طبقا ً للشروط والأحكام