Schneider | TMC2HOIS01 |Analogue input cartridge, Modicon M221, hoisting 2 analog I/O extension

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

cartridge M221 – hoisting 2 analog input – I/O extension This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This application cartridge is an option for Modicon M221C logic controller. It provides 2 dedicated analog inputs for controlling a load cell in hoisting application. The analog input types are current 0 to 20 mA, 4 to 20 mA and voltage 0 to 10 v. This product requires minimal installation and offers tremendous versatility. The serial line can be configured with Modbus RTU, Modbus ASCII or ASCII protocols. There is no insulation between analog input and internal logic. It is equipped with non removable screw terminal for electrical connection. Its dimensions are 35mm (Width) x 15mm (Depth) x 41mm (Height). It weighs 0.015kg. This product is certified by CE, IACS E10, CSA, RCM, LR, ABS, DNV-GL, EAC and CULus. It meets EN/IEC 61010-2-201, EN/IEC 61131-2 and EN/IEC 60664-1 standards. This cartridge is compatible with Modicon M221C PLC.

Schneider | TMC2PACK01 |Analogue input cartridge, Modicon M221, packaging 2 analog inputs, I/O extension

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

cartridge M221 – packaging 2 analog inputs – I/O extension This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This application cartridge is an option for Modicon M221C logic controller. It provides 2 dedicated analog inputs for controlling the temperature on a packaging machine. The analog input types are current 0 to 20 mA, 4 to 20 mA and voltage 0 to 10 v. This product requires minimal installation and offers tremendous versatility. The input cable type is twisted shielded pairs cable. The electrical connection is 3x 1.5mm², on 2 screw terminal blocks with pitch 3.81mm adjustment for inputs. The max. cable distance between devices is lower than 30m for input. There is no insulation between analog input and internal logic. It is equipped with non removable screw terminal for electrical connection. Its dimensions are 35mm (Width) x 15mm (Depth) x 41mm (Height). It weighs 0.015kg. This product is certified by CE, IACS E10, CSA, RCM, LR, ABS, DNV-GL, EAC and CULus. It meets EN/IEC 61010-2-201, EN/IEC 61131-2 and EN/IEC 60664-1 standards. This cartridge is compatible with Modicon M221C PLC.

Schneider | TMC2SL1 |communication cartridge module, Modicon M221, 1 serial line extension

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This serial line cartridge is a communication extension which support transmission rate 1.2kbps to 115.2kbps for bus length of 15m for RS485 and 3m for RS232. This product requires minimal installation and offers tremendous versatility. There is no insulation between lines and internal logic. It has non isolated serial link communication port protocols like Modbus master/slave and RTU/ASCII or SoMachine-Network. Its dimensions are 35mm (Width) x 15mm (Depth) x 41mm (Height). It weighs 0.015kg. This cartridge is compatible with Modicon M221C PLC. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks

Schneider | TMC2TI2 |analogue input cartridge, Modicon M221, 2 temperature inputs, IO extension

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This analogue input cartridge provides 2 temperature inputs with 14bit input resolution. This product requires minimal installation and offers tremendous versatility. The maximum twisted shielded pairs cable distance between devices is <30m for input. There is no insulation between analogue input and internal logic. It is furnished with screw terminal for electrical connection. Its dimensions are 35mm (Width) x 15mm (Depth) x 41mm (Height). It weighs 0.015kg. This cartridge is compatible with Modicon M221C PLC. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks

Schneider | TMCR2AI2 |cartridge M200 – 2 analog current inputs

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This product is part of the Modicon Easy M200 range, an offer of logic controllers for up to 168 I/O, 2 axis motion control. This analogue input cartridge provides 2 inputs with 12bit input resolution. It is an analogue input cartridge with a signal current of 4mA to 20mA, 0mA to 20mA and a signal voltage of 0V to 10V. The maximum twisted shielded pairs cable distance between devices is <30m for input. There is no insulation between analogue input and internal logic. It is furnished with screw terminal blocks for electrical connection with pitch 3.81mm adjustment for inputs. Its dimensions are 35mm (Width) x 15mm (Depth) x 41mm (Height). It weighs 0.012kg. This product is compatible with Modicon Easy M200 logic controllers. Modicon Easy M200 controllers are entry-level products perfectly suited to meet specific needs of emerging markets at an affordable price without compromise. Modicon Easy M200 logic controllers, the best performance/price ratio solutions for your small automation systems requiring flexibility and simple motion.

Schneider | TMCR2AM3 |cartridge M200 – 2 Analog inputs / 1 Analog output

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

Schneider Electric TMCR Series I/O module for Use with Easy Modicon M200, Analog, Analogue

Schneider | TMCR2AQ2C |cartridge M200 – 2 analog current outputs

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

Schneider Electric TMCR Ausgangsmodul für Easy Modicon M200 Easy Modicon M200 Analog OUT, 41 x 15 x 35 mm

Schneider | TMCR2AQ2V |cartridge M200 – 2 analog voltage outputs

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

Schneider Electric TMCR Ausgangsmodul für Easy Modicon M200 Easy Modicon M200 Analog OUT, 41 x 15 x 35 mm

Schneider | TMCR2DM4U |cartridge M200 – 2 Digital inputs and 2 Transistor sink outputs

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

cartridge M200 – 2 Digital inputs and 2 Transistor sink outputs

Schneider | TMCR2SL1 |cartridge M200 – 1 serial line – communication extension

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

cartridge M200 – 1 serial line – communication extension

Schneider | TMCR2TI2 |cartridge M200 – 2 temperature inputs – I/O extension

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

cartridge M200 – 2 temperature inputs – I/O extension

Schneider | TMH2GDB |graphic display, Modicon M221, unit, 240 x 160pixels

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This graphic display unit features a backlit colour STN LCD display. The display supports 240 x 160 pixels of resolution with monochrome display colour. The unit is equipped with RJ45 for communication and power supply. The keypad contains 4 configurable keys and 6 keys for navigation. It is an IP20 and IP65 rated product. Its dimensions are 80mm (Width) x 63mm (Depth) x 126mm (Height). It weighs 0.17kg. This product is certified by CE and CULus. It meets EN/IEC 61131-2 and EN/IEC 61010-2-201 standards. This display is compatible with Modicon M221 logic controller. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks

Schneider | TPRAN2X1 |Analog IO module, TeSys island, 2 inputs, 1 output, 24VDC, Twisted shielded pairs cable

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island analog IO module, 2 analog inputs, 1 analog output. Connected to a TPRBC bus coupler it is used for advanced control functions (TeSys avatars). Two analog inputs can be configured for measurement of voltage (-10/+10V, 0/+10V), current (0-20mA, 4-20mA) or temperature probes (Ni, Pt, thermocouples). One analog output can be configured for driving voltage source (-10/+10V, 0/+10V) or current source (0-20mA, 4-20mA). Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRBCEIP |Bus coupler, TeSys island, 24VDC, Ethernet switch (EtherNet IP / Modbus TCP)

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over EtherNet/IP or Modbus TCP. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides two RJ45 ports for EtherNet/IP or Modbus TCP, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified, Green Premium compliant (RoHS/REACh).

Schneider | TPRBCPFB |TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over PROFIBUS DP. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides one D-Sub port for PROFIBUS DP, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified, Green Premium compliant (RoHS/REACh).

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over PROFIBUS DP. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides one D-Sub port for PROFIBUS DP, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified, Green Premium compliant (RoHS/REACh).

Schneider | TPRBCPFN |TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over PROFINET IO. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides two RJ45 ports for PROFINET IO, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified, Green Premium compliant (RoHS/REACh).

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island bus coupler, point of connection between a TeSys island configuration (group of starters) and an automation system over PROFINET IO. It performs all functions for the application (TeSys avatars), selectable and configurable through SoMove or MachineExpert. For diagnostics and maintenance of the TeSys island, a web server (OMT) is embedded. To be supplied externally by 24V DC, it provides two RJ45 ports for PROFINET IO, one RJ45 service port over Ethernet, one micro SD card port, and a port for the internal bus interconnecting the modules of the island. Mounting on DIN rail, together with the other modules of the TeSys island configuration, the bus coupler is the module on the most left position. Multi standards certified (IEC, UL, CSA, CCC, EAC), cybersecurity Achilles Level 2 certified, Green Premium compliant (RoHS/REACh).

Schneider | TPRDG4X2 |Digital IO module, TeSys island, 4 inputs, 2 outputs, 24VDC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island digital IO module, 4 digital inputs 24V DC, 2 digital outputs 24V DC. Connected to a TPRBC bus coupler it is used for advanced control functions (TeSys avatars). It can be used to control external power switching devices when associated to a TPRPM power module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRPM009 |Power module, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island power module, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRPM038 |Power module, TeSys island, 40A AC-1, 38A AC-3, 18.5kW, 20hp

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island power module, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 38A and motors up to 18.5kW@400V / 20hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRPM080 |Power module, TeSys island, 80A at AC-1, 80A at AC-3, 37kW, 50hp

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island power module, 3 poles, 80A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 80A and motors up to 37kW@400V / 40hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 4-80A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRST009 |Motor starter, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp, DOL type

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island direct starter, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRST025 |Motor starter, TeSys island, 30A at AC-1, 25A at AC-3, 11kW, 15hp, DOL type

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island direct starter, 3 poles, 25A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 25A and motors up to 11kW@400V / 15hp@480V. It provides motor protection functions including thermal overload (setting 0.5-25A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRST038 |Motor starter, TeSys island, 40A at AC-1, 38A at AC-3, 18.5kW, 20hp, DOL type

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island direct starter, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 38A and motors up to 18,5kW@400V / 20hp@480V. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRST065 |Motor starter, TeSys island, 80A at AC-1, 65A at AC-3, 30kW, 40hp, DOL type

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island direct starter, 3 poles, 65A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 65A and motors up to 30kW@400V / 40hp@480V. It provides motor protection functions including thermal overload (setting 3.35-65A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRST080 |Motor starter, TeSys island, 80A at AC-1, 66A at AC-3, 37kW, 40hp, DOL type

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island direct starter, 3 poles, 80A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 80A and motors up to 37kW@400V / 40hp@480V. It provides motor protection functions including thermal overload (setting 4-80A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TPRVM001 |Voltage interface module, TeSys island, 690VAC 47-63 Hz, Isolated switching input for safe stop

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TeSys island voltage interface module, 100-690V / 47-63Hz. Connected to a TPRBC bus coupler it measures the mains voltages powering the loads. It provides the voltage values for power and energy calculation, calculates the RMS values and phase sequence. Voltage measurement range 100-690 V +/- 5 %, phase frequency measurement range 47-63 Hz +/- 1 Hz in single phase or 3-phase systems. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider | TR25D3R1604TPE |TransferPacT Remote, 160A, 400V, 3P, Remote, frame 250A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TransferPacT Remote, 160A, 400V, 3P, Remote, frame 250A

Schneider | TR25D3R2004TPE |TransferPacT Remote, 200A, 400V, 3P, Remote, frame 250A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TransferPacT Remote, 200A, 400V, 3P, Remote, frame 250A

Schneider | TR25D3R2502TPE |TransferPacT Remote, 250A, 230V, 3P, Remote, frame 250A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TransferPacT Remote, 250A, 230V, 3P, Remote, frame 250A

Schneider | TR25D3R2504TPE |TransferPacT Remote, 250A, 400V, 3P, Remote, frame 250A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TransferPacT Remote, 250A, 400V, 3P, Remote, frame 250A

Schneider | TR25D4R1604TPE |TransferPacT Remote, 160A, 400V, 4P, Remote, frame 250A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TransferPacT Remote, 160A, 400V, 4P, Remote, frame 250A

Schneider | TR25D4R2004TPE |TransferPacT Remote, 200A, 400V, 4P, Remote, frame 250A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

TransferPacT Remote, 200A, 400V, 4P, Remote, frame 250A