Schneider | 48612 |rod interlocking for fixed or drawout – for Masterpact NW08..63

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

rod interlocking for fixed or drawout – for Masterpact NW08..63

Schneider | 50437 |Closed toroid A type, VigiPacT, Vigilohm, TA30, inner diameter 30mm, rated current 65A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 65A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 30 millimeters and the weight is 0.120kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 15 millimeters. The maximum cross section per phase (R, S, T, N) is 25mm² for a copper conductor.

Schneider | 50438 |Closed toroid A type, VigiPacT, Vigilohm, PA50, inner diameter 50mm, rated current 85A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 85A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 50 millimeters and the weight is 0.200kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 25 millimeters. The maximum cross section per phase (R, S, T, N) is 50mm² for a copper conductor.

Schneider | 50439 |Closed toroid A type, VigiPacT, Vigilohm, IA80, inner diameter 80mm, rated current 160A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 160A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 80 millimeters and the weight is 0.420kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 40 millimeters. The maximum cross section per phase (R, S, T, N) is 95mm² for a copper conductor.

Schneider | 50440 |Closed toroid A type, VigiPacT, Vigilohm, MA120, inner diameter 120mm, rated current 250A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 250A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 120 millimeters and the weight is 0.450kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 60 millimeters. The maximum cross section per phase (R, S, T, N) is 240mm² for a copper conductor.

Schneider | 50441 |Closed toroid A type, VigiPacT, Vigilohm, SA200, inner diameter 200mm, rated current 400A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 400A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 200 millimeters and the weight is 1.320kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 100 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 185mm² for a copper conductor.

Schneider | 50442 |Closed toroid A type, VigiPacT, Vigilohm, GA300, inner diameter 300mm, rated current 630A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 630A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 300 millimeters and the weight is 2.280kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 150 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 240mm² for a copper conductor.

Schneider | 51207 |varmeter EasyLogic PFC Controller RT6

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

The Varlogic controllers permanently monitor the reactive power of the installation. This device also control the connection and disconnection of capacitor steps in order to obtain the targeted power factor. In case of overvoltage, low power factor or over compensation an alarm relay will activate. The user can parameter the power factor from 0.85 induct to 1. New control algorithm designed to reduce the number of switching operations and quickly attain the targeted power factor. This version include 6 step output contacts for a range of compensations. Output contacts are calibrated for 3 amps load at 250 V or 1 amp load at 400 V. The power supply allow voltage input from 320 to 460 V The dimensions of the controller are 143 mm in width, 143 mm in height, 67 mm in depth for a product weight of 800 g. Cerified for Electromagnetic Compatibility with IEC 61326, IEC 61000-6-2 and IEC 61000-6-4. A 139 mm by 139 mm swithcboard cut-out will be necessary for the flush panel mounting.,,

Schneider | 51213 |EasyLogic PFC Controller RT12 step 440V

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

Varlogic PF Controller RT12 step 440V,
The Varlogic controllers permanently monitor the reactive power of the installation. This device also control the connection and disconnection of capacitor steps in order to obtain the targeted power factor. In case of overvoltage, low power factor or over compensation an alarm relay will activate. The user can parameter the power factor from 0.85 induct to 1. New control algorithm designed to reduce the number of switching operations and quickly attain the targeted power factor. This version include 12 step output contacts for a range of compensations. Output contacts are calibrated for 3 amps load at 250 V or 1 amp load at 400 V. The power supply allow voltage input from 320 to 460 V The dimensions of the controller are 143 mm in width, 143 mm in height, 67 mm in depth for a product weight of 800 g. Cerified for Electromagnetic Compatibility with IEC 61326, IEC 61000-6-2 and IEC 61000-6-4. A 139 mm by 139 mm swithcboard cut-out will be necessary for the flush panel mounting.

Schneider | 54446 |external battery module, rechargeable, input 24 VDC, output 24 VDC / 40 mA max, 4h autonomy

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

external battery module, rechargeable, input 24 VDC, output 24 VDC / 40 mA max, 4h autonomy

Schneider | 56053 |Rectangular sensor L1 type, VigiPacT, 280mmx115mm, 1600A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to VigiPacT type A residual current protection and monitoring relays. It allows the measurement of a current rating up to 1600A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner dimensions of the toroid are 280mm X 155mm and the weight is 11kg. The wiring size must be from 0.5 to 2.5 mm². The wiring length should not exceed 10m.

Schneider | 56054 |Rectangular sensor L2 type, VigiPacT, 470mmx160mm, 3200A

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This toroid is dedicated to VigiPacT type A residual current protection and monitoring relays. It allows the measurement of a current rating up to 3200A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner dimensions of the toroid are 470mm X 160mm and the weight is 20kg. The wiring size must be from 0.5 to 2.5 mm². The wiring length should not exceed 10m.

Schneider | 56130 |Residual current protection relay, VigiPacT RH10M, 30mA, 220/240VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 30mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56135 |Residual current protection relay, VigiPacT RH10M, 300mA, 220/240VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 300mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56140 |Residual current protection relay, VigiPacT RH10M, 30mA, 380/415VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 380/415VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 30mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56145 |Residual current protection relay, VigiPacT RH10M, 300mA, 380/415VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH10M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 380/415VAC 50/60Hz. It is a type A earth-leakage protection class. The current sensitivity (IDn) is fixed to 300mA. The time delay (Dt) is instantaneous. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000VAC 50/60/400Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56163 |Residual current protection relay, VigiPacT RH21M, 30mA or 300mA, 220/240VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH21M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. The current sensitivity is selectable with 2 thresholds 30 mA and 300 mA. The time delay is instantaneous 0.06s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56164 |Residual current protection relay, VigiPacT RH21M, 30mA or 300mA, 380/415VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH21M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 380/415VAC 50/60Hz. The current sensitivity is selectable with 2 thresholds 30 mA and 300 mA. The time delay is instantaneous 0.06s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56173 |Residual current protection relay, VigiPacT RH99M, 30mA-30A, 220/240VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH99M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56174 |Residual current protection relay, VigiPacT RH99M, 30mA-30A, 380/415VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH99M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 380/415VAC 50/60Hz. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56193 |Residual current monitoring relay, VigiPacT RH99M, 30mA-30A, 220/240VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH99M is a DIN rail mounting residual current monitoring relay. It monitor drops in electrical insulation due to ageing of cables or extensions in the installation. It measures the earth leakage current in an electrical installation via its associated toroid. A control signal is issued by the relay when the residual-current operating threshold is overrun. The operational supply voltage is 220/240VAC 50/60Hz. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. There is an automatic reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | 56194 |Residual current monitoring relay, VigiPacT RH99M, 30mA-30A, 380/415VAC 50/60Hz, DIN rail mounting

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

VigiPacT RH99M is a DIN rail mounting residual current monitoring relay. It monitor drops in electrical insulation due to ageing of cables or extensions in the installation. It measures the earth leakage current in an electrical installation via its associated toroid. A control signal is issued by the relay when the residual-current operating threshold is overrun. The operational supply voltage is 380/415VAC 50/60Hz. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. There is an automatic reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.

Schneider | A9A26904 |Auxiliary contact, Acti9 A9A, iOF, 1 C/O, 100mA to 6A, 24VAC to 415VAC, 24-130 VDC, bottom connection

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

Auxiliary contact, Acti9 A9A, iOF, 1 C/O, 100mA to 6A, 24VAC to 415VAC, 24-130 VDC, bottom connection

Schneider | A9A26907 |padlocking device, Acti9, set of 10

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 product is a padlocking device is used to padlock in open or closed position. It is dedicated to Acti9 iC60, iID, iDPN Vigi, iSW-NA. The padlock diameter is from 3mm to 6mm. The sealable maximum diameter is 1.2mm. The locking in ON position does not prevent tripping of the breaker in the event of faults. This yellow padlocking accessory is mounted on the front of the product to be protected. This mounting device is suitable for iC60, iC60 + Vigi, iID, iDPN Vigi, iSW-NA, iSW Acti9. This product is suitable with IEC/EN 60947-2 standard compliant disconnection.

Schneider | A9C20731 |iCT 25A 1NO 230…240V 50Hz contactor

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 1P remote control device with 1 normally open contact. The In rated current is 25A for AC-7a and 8.5A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 230VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching small motors (fans, mixers) or HVAC system applications. This product is compliant with IEC/EN 61095 standard. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B. The maximum switching operations is 100 per day. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 2 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 81mm x (H) 18mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.

Schneider | A9C20732 |iCT 25A 2NO 230…240V 50Hz contactor

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 2P remote control device with 2 normally open contact. The In rated current is 25A for AC-7a and 8.5A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 230VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching small motors (fans, mixers) or HVAC system applications. This product is compliant with IEC/EN 61095 standard. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B. The maximum switching operations is 100 per day. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV.

Schneider | A9C20833 |contactor iCT – 3 poles – 3 NO – 25 A – 220..240 V AC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 3P remote control device with 3 normally open contacts. The In rated current is 25A for AC-7a and 8.5A for AC-7b. The Ue rated operational voltage is 400VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. This product is compliant with IEC/EN 61095 standard. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV.

Schneider | A9C20834 |contactor iCT – 4 poles – 4 NO – 25 A – 220..240 V AC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 2P remote control device with 2 normally open contacts. The rated current is 40A for AC-7a and 15A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 4 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 85mm x (H) 36mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.

Schneider | A9C20842 |contactor iCT – 2 poles – 2 NO – 40 A – 220..240 V AC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 2P remote control device with 2 normally open contacts. The rated current is 40A for AC-7a and 15A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 4 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 85mm x (H) 36mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.

Schneider | A9C20843 |contactor iCT – 3 poles – 3 NO – 40 A – 220..240 V AC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 3P remote control device with 3 normally open contacts. The rated current is 40A for AC-7a and 15A for AC-7b. The Ue rated operational voltage is 400VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute.

Schneider | A9C20844 |contactor iCT – 4 poles – 4 NO – 40 A – 220..240 V AC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 4P remote control device with 4 normally open contacts. The rated current is 40A for AC-7a and 15A for AC-7b. The Ue rated operational voltage is 400VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching small motors (fans, mixers) or HVAC system applications. This product is compliant with IEC/EN 61095 standard. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B. The maximum switching operations is 100 per day. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 6 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 85mm x (H) 54mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.

Schneider | A9C20862 |iCT 63A 2NO 220…240V 50Hz contactor

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Acti9 iCT is a modular contactor. It is a 2P remote control device with 2 normally open contacts. The rated current is 63A for AC-7a and 20A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 4 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 85mm x (H) 36mm x (D) 68.5mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.