Schneider | 33460 |Circuit breaker, ComPact NS630bN, 50kA/415VAC, Micrologic 2.0 trip unit, 630A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS630bN is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 630A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS630bN is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33461 |circuit breaker ComPact NS630bH, 70 kA at 415 VAC, Micrologic 2.0 trip unit, 630 A, fixed,3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

circuit breaker ComPact NS630bH, 70 kA at 415 VAC, Micrologic 2.0 trip unit, 630 A, fixed,3 poles 3d

Schneider | 33463 |circuit breaker ComPact NS630bN, 50 kA at 415 VAC, Micrologic 2.0 trip unit, 630 A, fixed,4 poles 4d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS630bN is a complete 4 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 630A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 4 poles version (327mm x 280mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS630bN is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33464 |circuit breaker Compact NS630bH – Micrologic 2.0 – 630 A – 4 poles 4t

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

circuit breaker Compact NS630bH – Micrologic 2.0 – 630 A – 4 poles 4t

Schneider | 33466 |Circuit breaker, ComPact NS800N, 50kA/415VAC, Micrologic 2.0 trip unit, 800A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS800N is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 800A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS800N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33467 |Circuit breaker, ComPact NS800H, 70kA/415VAC, Micrologic 2.0 trip unit, 800A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This ComPact NS800N is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 800A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. ComPact NS800H is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33469 |Circuit breaker, ComPact NS800N, 50kA/415VAC, Micrologic 2.0 trip unit, 800A, fixed, 4 poles 4d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS800N is a complete 4 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 800A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 4 poles version (327mm x 280mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS800N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33470 |circuit breaker Compact NS800H – Micrologic 2.0 – 800 A – 4 poles 4t

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

circuit breaker Compact NS800H – Micrologic 2.0 – 800 A – 4 poles 4t

Schneider | 33472 |Circuit breaker, ComPact NS1000N, 50kA/415VAC, Micrologic 2.0 trip unit, 1000A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS1000N is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1000A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS1000N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33473 |Circuit breaker, ComPact NS1000H, 70kA/415VAC, Micrologic 2.0 trip unit, 1000A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This ComPact NS1000H is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1000A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. ComPact NS1000H is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33475 |circuit breaker ComPact NS1000N, 50 kA at 415 VAC, Micrologic 2.0 trip unit, 1000 A, fixed,4 poles 4d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS1000N is a complete 4 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1000A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 4 poles version (327mm x 280mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS1000N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33476 |Circuit breaker, ComPact NS1000H, 70kA/415VAC, Micrologic 2.0 trip unit, 1000A, fixed, 4 poles 4d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS1000H is a complete 4 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1000A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 4 poles version (327mm x 280mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. ComPact NS1000H is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33478 |Circuit breaker, ComPact NS1250N, 50kA/415VAC, Micrologic 2.0 trip unit, 1250A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS1250N is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1250A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS1250N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33479 |Circuit breaker, ComPact NS1250H, 70kA/415VAC, Micrologic 2.0 trip unit, 1250A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This ComPact NS1250H is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1250A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. ComPact NS1250H is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33480 |Circuit breaker, ComPact NS1250N, 50kA/415VAC, Micrologic 2.0 trip unit, 1250A, fixed, 4 poles 4d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS1250N is a complete 4 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1250A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 4 poles version (327mm x 280mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS1250N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33481 |circuit breaker Compact NS1250H – Micrologic 2.0 – 1250 A – 4 poles 4t

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

circuit breaker Compact NS1250H – Micrologic 2.0 – 1250 A – 4 poles 4t

Schneider | 33482 |Circuit breaker, ComPact NS1600N, 50kA/415VAC, Micrologic 2.0 trip unit, 1600A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS1600N is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1600A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS1600N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33483 |Circuit breaker, ComPact NS1600H, 70kA/415VAC, Micrologic 2.0 trip unit, 1600A, fixed, 3 poles 3d

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This ComPact NS1600H is a complete 3 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 70kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1600A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 3 poles version (327mm x 210mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. ComPact NS1600H is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33484 |circuit breaker Compact NS1600N – Micrologic 2.0 – 1600 A – 4 poles 4t

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This Compact NS1600N is a complete 4 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. The circuit breaker can be manually operated with ON, OFF or “push to trip” buttons. This product embeds an electronic Micrologic 2.0 trip unit, with 1600A rating. Micrologic 2.0 trip unit provides adjustable long time and instantaneous protections. This 4 poles version (327mm x 280mm x 147mm) comes with a variety of optional functions and accessories. It is compliant with IEC 69947-1 and IEC60947-2 international standards and marine specifications. Compact NS1600N is part of Schneider Electric EcoStruxure Power architecture.

Schneider | 33485 |circuit breaker Compact NS1600H – Micrologic 2.0 – 1600 A – 4 poles 4t

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

circuit breaker Compact NS1600H – Micrologic 2.0 – 1600 A – 4 poles 4t

Schneider | 33661 |Standard opening voltage release MX, ComPacT NS630b/NS3200, fixed, 100/130V AC/DC, spare part

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This is a MX shunt trip release for Compact NS 630b to Compact NS 3200 devices. Its rated voltage is 100VDC to 130VDC or 100VAC to 130VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. It complies with IEC 60947-2 standard. Compact NS 630b to Compact NS 3200 device can be equipped with 1 MX or 1 MN auxiliary.

Schneider | 33662 |Standard opening voltage release MX, ComPacT NS630b/NS3200, fixed, 200/250V AC/DC, spare part

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This is a MX shunt trip release for Compact NS 630b to Compact NS 3200 devices. Its rated voltage is 200VDC to 250VDC or 200VAC to 250VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. It complies with IEC 60947-2 standard. Compact NS 630b to Compact NS 3200 device can be equipped with 1 MX or 1 MN auxiliary.

Schneider | 33664 |Standard opening voltage release MX, ComPacT NS630b/NS3200, fixed, 380/480VAC, spare part

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This is a MX shunt trip release for Compact NS 630b to Compact NS 3200 devices. Its rated voltage is 380VAC to 480VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage Un rises above 70% of its rated voltage Un. It complies with IEC 60947-2 standard. Compact NS 630b to Compact NS 3200 device can be equipped with 1 MX or 1 MN auxiliary.

Schneider | 33670 |Standard opening undervoltage release MN, ComPacT NS630b/NS3200, fixed, 100/130V AC/DC, spare part

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This is a MN undervoltage release for Compact NS 630b to Compact NS 3200 devices. Its rated voltage is 100VDC to 130VDC or 100VDC to 130VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage drops to a value below 35% of its rated voltage Un. It complies with IEC 60947-2 standard. Compact NS 630b to Compact NS 3200 device can be equipped with 1 MX or 1 MN auxiliary.

Schneider | 33671 |Standard opening undervoltage release MN, ComPacT NS630b/NS3200, fixed, 200/250V AC/DC, spare part

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This is a MN undervoltage release for Compact NS 630b to Compact NS 3200 devices. Its rated voltage is 200VDC to 250VDC or 200VAC to 250VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage drops to a value below 35% of its rated voltage Un. It complies with IEC 60947-2 standard. Compact NS 630b to Compact NS 3200 device can be equipped with 1 MX or 1 MN auxiliary.

Schneider | 33673 |Standard opening undervoltage release MN, ComPacT NS630b/NS3200, fixed, 380/480VAC, spare part

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This is a MN undervoltage release for Compact NS 630b to Compact NS 3200 devices. Its rated voltage is 380VAC to 480VAC 50/60Hz. It is an auxiliary used for emergency off or remote opening applications. This auxiliary opens the circuit breaker when the control voltage drops to a value below 35% of its rated voltage Un. It complies with IEC 60947-2 standard. Compact NS 630b to Compact NS 3200 device can be equipped with 1 MX or 1 MN auxiliary.

Schneider | 33682 |adjustable time delay relay for voltage release MN – 200/250 V AC/DC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

This time delay unit is an auxiliary that can be combined with an undervoltage release (MN). It must be associated with a 250VDC MN undervoltage release. It eliminates the risk of nuisance tripping due to transient voltage dips lasting from 200ms to 3s. Its power supply is 200-250VDC or 200-250VAC 50/60Hz. This time delay unit has 4 adjustable steps (0.5s – 1s – 1.5s – 3s). It is an external accessory and can be mounted in the switchboard.

Schneider | 33685 |non – adjustable time delay relay for voltage release MN – 200/250 V AC/DC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

non – adjustable time delay relay for voltage release MN – 200/250 V AC/DC

Schneider | 33799 |standard auxiliary contact, ComPact NS630b to NS1600, withdrawable, circuit breaker status SDE, 1 changeover contact

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

standard auxiliary contact, ComPact NS630b to NS1600, withdrawable, circuit breaker status SDE, 1 changeover contact

Schneider | 33800 |standard auxiliary contact, ComPact NS630b to NS1600, withdrawable, circuit breaker status SD, 1 changeover contact type

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

standard auxiliary contact, ComPact NS630b to NS1600, withdrawable, circuit breaker status SD, 1 changeover contact type

Schneider | 33801 |standard auxiliary contact, ComPact NS630b to NS1600, withdrawable, circuit breaker status OF, 1 changeover contact type

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

It is a single standard auxiliary contact for drawout Compact NS630b to 1600 devices. This auxiliary contact that provides OF remote information of the circuit breaker status. The OF contact (open/closed) indicates the position of the circuit breaker main contacts. There is one auxiliary contact model for OF, SD or SDE information, depending on where it is fitted in the device. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 6A and the minimum load is 100mA at 24 VDC. Utilization categories are AC12/AC13/DC12/DC14. Compact NS 630b to 1600 can be equipped with 3 OF auxiliary contacts. It complies with IEC 60947-5-1 standard.

Schneider | 33812 |Standard opening voltage release MX, MasterPact NT, ComPacT NS630b/NS1600, drawout, 100/130VDC, 100/130VAC

0.01جنيه Cashback

متاح بالطلب – تواصل معنا لمعرفة مدة التوريد

1.00جنيه

Standard opening voltage release MX, MasterPact NT, ComPacT NS630b/NS1600, drawout, 100/130VDC, 100/130VAC